The item comprises six Series 1 MIL-C-38999 connectors and a multi-conductor cable, which must meet the continuity, dielectric withstanding voltage, and insulation resistance tests specified in MIL-C-3885. It must also satisfy the moisture resistance, temperature cycling, low temperature flex life, and reversion of polyurethane and polyacrylic materials tests outlined in MIL-C-3885.